Structural Testing

EMA provides structural testing on any building or roof system including concrete roofs, gravel and shingled roofs. After hurricanes, or natural disasters including lightening strikes the roof may get damaged. That is where we send or professional engineers and inspectors to do a thorough inspections of roofing and intent of damage for insurance claim purpose and repairs.

We also perform various structural testing inspections including intial tig-tag, structural in progress and structural final inspections for shingled, tile roofs. We also perform roof static uplift test TAS-105, TAS-106, Bell chamber (TAS-124), Thermal Imaging etc. Various Services are performed and a Sealed and Signed report is prepared for the client.

Roof Testing

Tin-cap inspection (Sealed)

Mop-in-Progress (Sealed)

Final Inspection (Sealed)

Bell Chamber TAS 124

Fastener Pull Test (TAS-1050

REBAR LOCATION BEAMS, COLUMNS , SLABS

Tile Uplift test (TAS-106)

Thermal Imaging/ Infrared inspections

We also perform structural roofing inspections for all shingle, metal & clay tile or concrete tile roofs as per Florida building code chapter 15. Please call for our services.

Inspections & Testing

EMA Engineers performs detailed, professional visual inspections with state-of-the-art moisture detection devices and gives thorough explanations with digital pictures.

AFFILLIATED

Florida Registered Professional Engineer

Mississippi Professional Engineers

Louisiana Professional engineers

Special Inspectors Florida

SBCCI Building inspector.

TAS 105- Fastener Withdrawal Resistance Testing

TAS 106- Uplift Resistance Testing Tile Roof

TAS 109- Polyurethane Foam Roofing (pending certification).

TAS 124- Existing and New Roof Wind Uplift Resistance Testing

TAS 126- Roof Moisture Survey _ Nuclear/Infrared (pending certification)

INSPECTION PROCEDURES

The starting point of the structural testing Inspection should be the interior of the building. The interior walls and ceilings should be checked for signs of water staining. After inspecting the interior a thorough inspection of the exterior walls should be made along with the roof system.

service preconstruction planning
service project management

Field Membrane – What to look for:

Open seams excessive blisters, wrinkles, ridges or areas of non-adhered membrane.
Worn spots holes or deteriorated areas of the membrane.
Deteriorated, areas of surface coating on the membrane.
Adequate, drainage and pending problems of the membrane.
Areas around equipment that may have been degraded by leaks or spills or punctured by dropped equipment parts.

Leak Maintenance Procedure:

Protect the interior
Remove excess water from the roof. Check roof drains and scupper boxes to be certain that they are functional. Excessive pending on the roof may cause roof system damage, structural damage or even roof collapse.
Locate the source of the leak by locating the point and the roof above the leak in the building’s interior.
Perform necessary repairs. Once the source of a leak is located, the materials and procedure used to make the roof watertight will be determined by the roofing professional.